Protective Door Industries
15700 Lathrop Ave.
Harvey, IL 60426-5118
Ph: 708-331-2515
Fax: 708-331-2500
sales@protectivedoor.com
|
|
 |
 |
 |
|
|
 |
 |
 |
 |
|
|
 |
 |
 |
 |
|
|
 |
|
Blast / Pressure / Missile Chart | | Click on the PDF icon to view or download SonicbarĀ® Door Model technical specifications in PDF format. If Microsoft Word format is preferred,contact PDI direct. Note: Specifications are not to be changed or altered. Please do not insert hollow metal door standards. Special purpose doors are engineered to performance criteria and have their own unique attributes. Click on drawing number for sample details. More sample drawings are available, contact PDI direct.
Note: Drawings are proprietary and provided for reference purposes only. They are a general representation of the multitude of door and window systems PDI has designed and built, and not intended to be an exact representation of actual hardware requirements, door construction, wall conditions or anchorage. Contact Protective Door Industries Technical Department or call 708-225-3539 | |
PDI Blast / Pressure / Missile Selector Chart |
Sonicbar® Model Specifications |
Range |
Design Load |
Pressure Factor |
Rebound |
Architectural Configuration |
Latching Hardware Type |
Fire Label |
Nominal Door Thickness |
Sample Drawing |
DB-100 Door
 |
Very low range |
100 PSF to 244 PSF |
Static |
100% |
Single or pair |
Modified builders |
A, B, C, D |
1 3ā4" |
1379-1-S
1496-1-S
1442-2-P
|
DB-100-SS Door
 |
Low range |
100 PSF to 244 PSF |
Static |
100% |
Single or pair |
Modified builders |
Certificate of Noncombustible Construction |
1 3ā4" |
1392-1-S
|
DB-100-SL
 |
Low range |
100 PSF to 150 PSF |
Static |
100% |
Horizontal sliding |
As required |
Certificate of Noncombustible Construction |
2 3ā4" |
1500-3-SL
1500-5-SL
1500-6-SL
|
DB-150
 |
Nominally airtight |
Varies |
Varies |
Varies |
Single |
As required |
Certificate of Noncombustible Construction |
Varies |
Contact Factory |
DB-200
 |
Low range |
1 PSI to 3 PSI |
Static |
100% |
Single or pair |
SonicbarĀ® SH Series |
A, B, C, D |
2 3ā4" |
1320-2-S
1525-1-P
|
DB-200-SL
 |
Mid-range |
1 PSI to as required |
Static or dynamic |
100% or as calculated |
Horizontal sliding |
As required |
Certificate of Noncombustible Construction |
2 3ā4" or as required |
1500-4-SL
1500-5-SL
1500-6-SL
|
DB-200-VL
 |
Low to mid-range |
As required |
Static |
100% or as calculated |
Vertical lift |
As required |
Certificate of Noncombustible Construction |
2 3ā4" or as required |
VLSR
|
DB-10
 |
Mid-range |
6 PSI to 10 PSI |
Static |
100% |
Single or pair |
SonicbarĀ® SH Series |
A, B, C, D |
2 3ā4" |
1518-1-S
|
DB-X-1
 |
Mid-range |
Varies |
Dynamic |
As calculated |
Single or pair |
SonicbarĀ® SH Series |
Certificate of Noncombustible Construction |
2 1ā8" |
1463-1-S
1463-2-P
1463-3-P
|
DB-50
 |
High range |
Varies |
Static or dynamic |
Rebound % varies or as calculated |
Single, pair or sliding |
SonicbarĀ® SH Series |
Certificate of Noncombustible Construction |
As required |
Contact Factory |
DB-X
 |
Mid to high range |
Varies |
Dynamic |
As calculated |
Single or pair |
SonicbarĀ® SH Series |
Certificate of Noncombustible Construction |
As required |
Contact Factory |
DA-100
 |
Airtight, gastight |
Varies |
Varies |
Varies |
Single |
As required |
None |
Varies |
Contact Factory |
WB-X
 |
As required |
Varies |
Static or dynamic |
As specified |
None |
None |
None |
None |
1522-4
1362-12
|
|