Protective Door Industries
Sonicbar Doors and Hardware Home Quality Program History Contact Us  

PDI Protective Door Industries 15700 Lathrop Ave.
Harvey, IL 60426-5118 USA
708/331-2515
708/331-2500 Fax www.protectivedoor.com sales@protectivedoor.com

DT-200 FEMA 361
TORNADO RESISTANT Door Unit

PDI offers Door Model DT-200 FEMA 361, a single out-swing steel tornado resistant door compliant with FEMA’s 320/361 and ICC-500 storm shelter standards. This  criteria covers tornado forces that produce complex positive and negative pressures and impulses, and severe impact conditions. DOWNLOAD THIS AS PDF (for Printout)

WITHSTAND 2.09 PSI STATIC PRESSURE LOAD,UNSEATING DIRECTION FOR 5 SECONDS

WITHSTAND MISSILE PENETRATION —(3) HITS FROM 2X4 TRAVELING 100 mph

Features:
  1. RIGOROUS ALL WELDED STEELCONSTRUCTION
  2. 3’0” X 7’0” JAMB OPENING(nom. 915mm x 2130mm)
  3. 2 ¼” DOOR THICKNESS (nom. 57mm thk.)
  4. OUT-SWING DOOR
  5. 12GA. STEEL FACE SHEETS REINFORCEDWITH INTERNAL STEEL TUBE STIFFENERS
  6. 12GA. FORMED FRAME x DOUBLE RABBITPROFILE x 6 ¾” FRAME DEPTH x 3-SIDED
  7. (1 ½) PAIR PDI SONICBAR® BRANDSH-100-SS STAINLESS STEEL HINGES
    • HEAVY DUTY HINGES PREVENT SAGGING
    • SS HINGES WILL NOT RUST
  8. ANCHORAGE OPTIONS
    • WELD-IN
    • CMU HOOK - FIXED
    • POURED CONCRETE HOOK - FIXED
  1. FULLY INSULATED
  2. SPRING LOADED LATCHING CLOSESAUTOMATICALLY WITH ADDITION OFOPTIONAL DOOR CLOSER
  3. 12GA. CLOSER REINFORCEMENT
  4. PDI SONICBAR® BRAND SH-153PCPRESSURE RESISTANT MORTISED2-POINT HORIZONTAL LOCKSETx SS FINISH
    • MORTISED COMPONENTS FACTORYINSTALLED, ONLY TRIM SHIPPED LOOSE
    • HANDING: RHRB or LHRB
    • FACTORY PREPPED FOR KEY CYLINDER
    • EXTERIOR LEVER HANDLE
    • INTERIOR EXIT BAR or LEVER HANDLE
    • AND,
      • No surface mounted hardware
      • No 3-point latching, and
      • No bottom floor bolt
  5. FACTORY PRIMED WITH RUST INHIBITORCOMPATIBLE WITH HIGH PERFORMANCETOPCOATS
Compliance:
  • • Testing Facility: Wind Science and Engineering Research Center, Debris Impact Test Facility, Lubbock, TX.
  • • Product Type: Above Ground Shelter Door – FEMA 361 / ICC-500.
  • • Tests: Pressure and impact tests per guidelines of FEMA 320/361, ICC-500 Shelter Standard Tornado Protocol 4, andASTM E330.
  • • Test Report: No. 2012-0405A, Specimen No. 1 dated April 5, 2012, ‘Investigation of Wind Projectile Resistance of theLB Steel, LLC – Protective Door Ind. Above Ground Shelter Door’.
  • • Criteria: Resist tornado wind forces of 2.09 PSI unseating static equivalent pressure for 5 seconds. This relates to Zone 5per ASCE 7-05 for a corner zone, positive and negative pressures.Withstand missile penetration of (3) impacts from a 2”x4” wood stud weighing 15 lbs. traveling horizontally at100 mph, impact on exterior (hinge) side.

PDI’s DT-200 FEMA 361 door is intended for virtually any application – light duty to heavy industrial. And mostimportant, as in all PDI door systems, it’s built to protect lives and property.



                                           
           
               
                   

PDI Protective Door Industries 15700 Lathrop Ave.
Harvey, IL 60426-5118 USA
708/331-2515
708/331-2500 Fax www.protectivedoor.com sales@protectivedoor.com

               
               
                                   
           
       
           
               
                   

                        DT-200 FEMA 361
TORNADO RESISTANT Door Unit

               
               
Technical Data:
  • Standard: FEMA 320/361 and ICC-500 for ‘Above Ground Shelter Door’.
  • Pressure load: Withstand 2.09 PSI unseating static equivalent pressure for 5 sec.
  • Missile load: Withstand (3) impacts from a 2”x4” wood stud weighing 15 lbs. traveling horizontally at 100 mph, impact on exterior (hinge) side.
  • Fire rating: None.
  • Quality: ISO 9001:2008
  • Dimensions: 3’0” wide x 7’0” high (jamb opening) single swing. (Nom. 915mm wide x 2130mm high)
  • Door swing: Out-swing.
  • Frame: 12ga. formed frame x 6 ¾” depth x 3-sided x factory set-up and welded.
  • Anchorage: Check appropriate anchorage. See details below.
    • _______ Masonry / CMU hook anchors - fixed
    •  _______ Weld-in anchorage
    • _______ Poured concrete hook anchors - fixed
                   
                   
  • Door leaf: Flush 2 ¼” thk. (nom. 57mm) x 12ga. steel face sheets with reinforced stiffeners and fiberglass insulation. Approximate weight 300 lbs.
  • Hardware: PDI brand Sonicbar® SH-153PC 2-point mortised horizontal latchset x lever x exit  bar or lever x key cylinder (prep) x SS US32D finish. Function similar to classroom.
  • Handing: See handing chart. Fill in quantity.
    • _______ RHRB Right hand reverse bevel
    • _______ LHRB Left hand reverse bevel
  • Hinges: PDI brand Sonicbar® SH-100-SS stainless steel butt hinges x 6” x 6 3/32” x .165” x brushed finish x 3/8” dia. SS pin. Finish: Rust inhibitive metal primer. (Finish paint by others.)
  • Optional:
  • Door closer: Heavy duty closer x PA x aluminum finish.
  • Gasketing: (1) set PDI brand H-280W-SS stainless steel adjustable weatherstripping x neopreneseals x brushed finish; PDI brand H-344 sill seal xneoprene seal x USP finish and threshold.